Pepperl fuchs P+F KFD2-STC4-Ex1 Isolated barrier Transmitter Power Supply

description:1-channel isolated barrier,24 V DC supply (Power Rail),Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources...
BASIC INFO
Pepperl fuchs P+F KFD2-STC4-Ex1 Isolated barrier Transmitter Power Supply



 
SMART Transmitter Power Supply KFD2-STC4-Ex1
1-channel isolated barrier
24 V DC supply (Power Rail)
Input 2-wire and 3-wire SMART transmitters and 2-wire SMART current sources
Output 0/4 mA ... 20 mA
Terminals with test points
Up to SIL 2 acc. to IEC 61508
 
 
Function: KFD2-STC4-Ex1
 
This isolated barrier is used for intrinsic safety applications.
 
The device supplies 2-wire and 3-wire SMART transmitters in a hazardous area, and can also be used with 2-wire SMART current sources.
 
It transfers the analog input signal to the safe area as an isolated current value.
 
Digital signals may be superimposed on the input signal in the hazardous or safe area and are transferred bi-directionally.
 
If the HART communication resistance in the loop is too low, the internal resistance of 250 Ω between terminals 8 and 9 can be used.
 
Test sockets for the connection of HART communicators are integrated into the terminals of the device.



Datasheet excerpt: Technical data of  KFD2-STC4-Ex1
     
Product Description  
Input 0/4 mA ... 20 mA
Output 0/4 mA ... 20 mA
General specifications
Signal type Analog input
Functional safety related parameters
Safety Integrity Level (SIL) SIL 2
Supply
Connection Power Rail or terminals 14+, 15-
Rated voltage 20 ... 35 V DC
Ripple within the supply tolerance
Power dissipation 1.4 W
Power consumption 1.8 W
Input
Connection side field side
Connection terminals 1+, 2-, 3 or 5-, 6+
Input signal 0/4 ... 20 mA
Voltage drop ≤ 2.4 V at 20 mA (terminals 5, 6)
Input resistance ≤ 64 Ω terminals 2-, 3 ; ≤ 500 Ω terminals 1+, 3 (250 Ω load)
Available voltage ≥ 16 V at 20 mA terminals 1+, 3
Output
Connection side control side
Connection terminals 7-, 8+, 9
Load 0 ... 800 Ω at 20 mA
Output signal 0/4 ... 20 mA (overload > 25 mA)
Ripple max. 50 µA rms



Order Number:

KCD2-STC-Ex1    
KCD2-STC-Ex1.ES
KFD2-CRG2-Ex1.D
KFD2-HLC-Ex1.D
KFD2-HLC-Ex1.D.2W
KFD2-STC4-Ex1
KFD2-STC4-Ex1.2O
KFD2-STC4-Ex1.2O.H
KFD2-STC4-Ex1.H
KFD2-STC4-Ex2
KFU8-CRG2-Ex1.D
KCD2-STC-Ex1.2O
KCD2-STC-Ex1.2O.ES
KCD2-STC-Ex1.ES.SP
KCD2-STC-Ex1.SP
KFD2-STC3-Ex1
KFD2-STC4-Ex1-Y1
KFD2-STC4-Ex1.2O-Y1
KFD2-STC4-Ex1.ES
KFD2-STC4-Ex2-Y1
KFD2-STC5-Ex1
KFD2-STC5-Ex1.2O
KFD2-STC5-Ex1.2O.H
KFD2-STC5-Ex1.H
KFD2-STC5-Ex2
KFD2-STV4-Ex1.2O-1
KFD2-STV4-Ex2-1
KFD2-STV4-Ex2-2
KFD2-STV5-Ex1-1
KCD2-STC-Ex1.2O.DE
KFD2-HLC-Ex1.D.4S
KFD2-STV4-Ex1.2O-2
KFD2-STC4-Ex1
KFD2-STC4-Ex1-Y1
KFD2-STC4-Ex1.2O
KFD2-STC4-Ex1.2O-Y1
KFD2-STC4-Ex1.2O.H
KFD2-STC4-Ex1.H
KFD2-STV4-Ex1-1
KFD2-STV4-Ex1-2
KFD2-STV4-Ex1.2O-1
KFD2-STV4-Ex2-1
KFD2-STV4-Ex2-2
KFD2-STV4-Ex1.2O-2
KFD2-STC3-Ex1
KCD2-STC-Ex1-Y1
 
 
KFD2-CRG2-1.D
KFD2-STC5-1
KFD2-STC5-1.2O
KFD2-STC5-2
KFU8-CRG2-1.D
KFU8-VCR-1
KCD2-STC-1
KCD2-STC-1.2O
KCD2-STC-1.SP
KFD2-CR4-1
KFD2-CR4-1.2O
KFD2-STC4-1
KFD2-STC4-1.2O
KFD2-STC4-1.2O-3
KFD2-STC4-2
 
 
KCD2-SR-Ex1.LB
KCD2-SR-Ex2
KFA6-DU-Ex1.D
KFA6-ER-Ex1.W.LB
KFA6-SOT2-Ex2
KFA6-SR2-Ex1.W
KFA6-SR2-Ex1.W.LB
KFA6-SR2-Ex2.W
KFA6-SR2-Ex2.W.IR
KFD2-DU-Ex1.D
KFD2-ELD-Ex16
KFD2-ER-Ex1.W.LB
KFD2-SH-Ex1
KFD2-SOT3-Ex1.LB
KFD2-SOT3-Ex1.LB.IO
KFD2-SOT3-Ex2
KFD2-SOT3-Ex2.IO
KFD2-SR2-Ex1.W
KFD2-SR2-Ex1.W.LB
KFD2-SR2-Ex2.W
KFD2-SR3-Ex2.2S
KFD2-SRA-Ex4
KFD2-ST3-Ex1.LB
KFD2-ST3-Ex2
KHA6-SH-Ex1
KCD2-SON-Ex1
KCD2-SOT-Ex1.LB
KCD2-SOT-Ex2
KCD2-SOT-Ex2.SP
KCD2-SR-Ex1.LB.SP
KCD2-SR-Ex2.SP
KCD2-ST-Ex1.LB
KCD2-ST-Ex2
KFA5-SOT2-Ex2
KFA5-SR2-Ex1.W
KFA5-SR2-Ex1.W.LB
KFA5-SR2-Ex2.W
KFA5-SR2-Ex2.W.IR
KFD2-SOT3-Ex2.IO-Y1
KCD2-SON-Ex1.R1
KCD2-SON-Ex1.R2
KCD2-SON-Ex1.R3
KCD2-SON-Ex1.SP
KCD2-SON-Ex2
KCD2-SON-Ex2.R1
KCD2-SON-Ex2.R2
KCD2-SON-Ex2.R3
KCD2-SON-Ex2.SP
KCD2-SOT-Ex1.LB.SP
KCD2-ST-Ex1.LB.SP
KCD2-ST-Ex2.SP
KFA4-SR2-Ex2.W
KFA5-DU-Ex1.D
KFA4-SR2-Ex1.W
KFA4-SR2-Ex1.W.LB
KFD2-SOT2-Ex1.LB
KFD2-SOT2-Ex1.LB.IO
KFD2-SOT2-Ex2
KFD2-SOT2-Ex2.IO
KFD2-SOT2-Ex2.IO-Y181008
KFD2-SR2-Ex2.2S
KFD2-ST2-Ex1.LB
KFD2-ST2-Ex2
KFD2-SH-Ex1.T
KFD2-SH-Ex1.T.OP



Any inquires, please feel free to contact us via E-mail, thanks!
-----------------------------------
Lily
 
HONGKONG XIEYUAN TECH CO., LIMITED
 
T: 86-027-85568699  F: 86-027-85309780 
E-mail: lily@hkxytech.com
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan, Hubei, China
Web: www.hkxytech.com

Pre:P+F Pepperl+fuchs KFD2-STV4-Ex1.2O-2 Transmitter Power Supply Isolated barrier Next:Pepperl fuchs P+F KFD2-STV4-Ex1-1 Transmitter Power Supply Isolated barrier