BASIC INFO
Pepperl+fuchs P+F KFU8-CRG2-1.D Signal conditioner Transmitter Power Supply
Transmitter Power Supply KFU8-CRG2-1.D
1-channel signal conditioner
Universal usage at different power supplies
Input 2-wire and 3-wire transmitters and 2-wire current sources
Output 0/4 mA ... 20 mA
2 relay contact outputs
Adjustable energized/de-energized delay
Programmable high/low alarm
Linearization function (max 20 points)
Line fault detection (LFD)
Up to SIL 2 acc. to IEC 61508/IEC 61511
Function: KFU8-CRG2-1.D
This signal conditioner provides the galvanic isolation between field circuits and control circuits.
The device supplies 2-wire and 3-wire transmitters, and can also be used with current sources.
Two relays and an active 0/4 mA ... 20 mA current source are available as outputs. The relay contacts and the current output can be integrated in security-relevant circuits. The current output is easily scaled.
On the display the measured value can be indicated in various physical units.
The device is easily configured by the use of keypad or with the PACTware configuration software.
The input has a line fault detection.
Order Number:
KCD2-STC-Ex1
KCD2-STC-Ex1.ES
KFD2-CRG2-Ex1.D
KFD2-HLC-Ex1.D
KFD2-HLC-Ex1.D.2W
KFD2-STC4-Ex1
KFD2-STC4-Ex1.2O
KFD2-STC4-Ex1.2O.H
KFD2-STC4-Ex1.H
KFD2-STC4-Ex2
KFU8-CRG2-Ex1.D
KCD2-STC-Ex1.2O
KCD2-STC-Ex1.2O.ES
KCD2-STC-Ex1.ES.SP
KCD2-STC-Ex1.SP
KFD2-STC3-Ex1
KFD2-STC4-Ex1-Y1
KFD2-STC4-Ex1.2O-Y1
KFD2-STC4-Ex1.ES
KFD2-STC4-Ex2-Y1
KFD2-STC5-Ex1
KFD2-STC5-Ex1.2O
KFD2-STC5-Ex1.2O.H
KFD2-STC5-Ex1.H
KFD2-STC5-Ex2
KFD2-STV4-Ex1.2O-1
KFD2-STV4-Ex2-1
KFD2-STV4-Ex2-2
KFD2-STV5-Ex1-1
KCD2-STC-Ex1.2O.DE
KFD2-HLC-Ex1.D.4S
KFD2-STV4-Ex1.2O-2
KFD2-STC4-Ex1
KFD2-STC4-Ex1-Y1
KFD2-STC4-Ex1.2O
KFD2-STC4-Ex1.2O-Y1
KFD2-STC4-Ex1.2O.H
KFD2-STC4-Ex1.H
KFD2-STV4-Ex1-1
KFD2-STV4-Ex1-2
KFD2-STV4-Ex1.2O-1
KFD2-STV4-Ex2-1
KFD2-STV4-Ex2-2
KFD2-STV4-Ex1.2O-2
KFD2-STC3-Ex1
KCD2-STC-Ex1-Y1
KFD2-CRG2-1.D
KFD2-STC5-1
KFD2-STC5-1.2O
KFD2-STC5-2
KFU8-CRG2-1.D
KFU8-VCR-1
KCD2-STC-1
KCD2-STC-1.2O
KCD2-STC-1.SP
KFD2-CR4-1
KFD2-CR4-1.2O
KFD2-STC4-1
KFD2-STC4-1.2O
KFD2-STC4-1.2O-3
KFD2-STC4-2
KCD2-SR-Ex1.LB
KCD2-SR-Ex2
KFA6-DU-Ex1.D
KFA6-ER-Ex1.W.LB
KFA6-SOT2-Ex2
KFA6-SR2-Ex1.W
KFA6-SR2-Ex1.W.LB
KFA6-SR2-Ex2.W
KFA6-SR2-Ex2.W.IR
KFD2-DU-Ex1.D
KFD2-ELD-Ex16
KFD2-ER-Ex1.W.LB
KFD2-SH-Ex1
KFD2-SOT3-Ex1.LB
KFD2-SOT3-Ex1.LB.IO
KFD2-SOT3-Ex2
KFD2-SOT3-Ex2.IO
KFD2-SR2-Ex1.W
KFD2-SR2-Ex1.W.LB
KFD2-SR2-Ex2.W
KFD2-SR3-Ex2.2S
KFD2-SRA-Ex4
KFD2-ST3-Ex1.LB
KFD2-ST3-Ex2
KHA6-SH-Ex1
KCD2-SON-Ex1
KCD2-SOT-Ex1.LB
KCD2-SOT-Ex2
KCD2-SOT-Ex2.SP
KCD2-SR-Ex1.LB.SP
KCD2-SR-Ex2.SP
KCD2-ST-Ex1.LB
KCD2-ST-Ex2
KFA5-SOT2-Ex2
KFA5-SR2-Ex1.W
KFA5-SR2-Ex1.W.LB
KFA5-SR2-Ex2.W
KFA5-SR2-Ex2.W.IR
KFD2-SOT3-Ex2.IO-Y1
KCD2-SON-Ex1.R1
KCD2-SON-Ex1.R2
KCD2-SON-Ex1.R3
KCD2-SON-Ex1.SP
KCD2-SON-Ex2
KCD2-SON-Ex2.R1
KCD2-SON-Ex2.R2
KCD2-SON-Ex2.R3
KCD2-SON-Ex2.SP
KCD2-SOT-Ex1.LB.SP
KCD2-ST-Ex1.LB.SP
KCD2-ST-Ex2.SP
KFA4-SR2-Ex2.W
KFA5-DU-Ex1.D
KFA4-SR2-Ex1.W
KFA4-SR2-Ex1.W.LB
KFD2-SOT2-Ex1.LB
KFD2-SOT2-Ex1.LB.IO
KFD2-SOT2-Ex2
KFD2-SOT2-Ex2.IO
KFD2-SOT2-Ex2.IO-Y181008
KFD2-SR2-Ex2.2S
KFD2-ST2-Ex1.LB
KFD2-ST2-Ex2
KFD2-SH-Ex1.T
KFD2-SH-Ex1.T.OP
Any inquires, please feel free to contact us via E-mail, thanks!
-----------------------------------
Lily
HONGKONG XIEYUAN TECH CO., LIMITED
T: 86-027-85568699 F: 86-027-85309780
E-mail: lily@hkxytech.com
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan, Hubei, China
Web: www.hkxytech.com