YOKOGAWA ESD Analog Input Module SAI143
n STANDARD SPECICATIONS
l Current Input Module
This module inputs 4 to 20 mA signals from the field.
The SAI143 can be made dual redundant.
Item |
Specifications |
||
Model |
SAI143 (*1) |
||
Number of input channels |
16-channel, module isolation (*5) |
||
Rated input range |
4 to 20 mA |
||
Permissible input range |
0 to 25 mA |
||
Input impedance during Power-ON |
250 + Voltage drop in the input protection circuit inside the module |
(*6) |
|
Current value |
|||
Input impedance during Power-OFF |
500 k minimum |
||
Rated accuracy |
SAI143-S : ±16 µA (Input range 1 to 23 mA) |
||
SAI143-H : ±16 µA (Input range 0.05 to 23 mA) (*3) (*4) |
|||
Data update frequency |
40 ms |
||
Temperature drift |
±16 µA/10 °C |
||
Transmitter power supply |
16.15 V minimum (at 20 mA) |
||
26.4 V maximum (at 0 mA) |
|||
(Output current limit: 25 mA) |
|||
2/4-wire setting |
Individual channel setting |
||
Changed by setting pins |
|||
Withstand voltage |
1.5 kV AC between input signal and system for 1 minute (*2) |
||
Maximum current consumption |
5 V system: 320 mA, |
||
24 V system: 550 mA |
|||
Weight |
Approx. 0.34 kg (For pressure clamp terminal block or MIL cable) |
||
Approx. 0.39 kg (With signal cable interface adapter) |
|||
External connection |
Pressure clamp terminal |
||
MIL cable |
|||
Dedicated signal cable |
|||
Support PRM |
Available (SAI143-H) |
YOKOGAWA ESD Analog Input Module SAI143-H53
n MODEL AND SUFFIX CODES
|
|
Description |
Model |
SAI143 |
Analog Input Module (4 to 20 mA, 16-channel, module isolation) |
Suffix Codes |
-S |
Standard type |
-H |
With HART communication [Release: R1.02.00] (*1) |
|
5 |
For pressure clamp terminal block or MIL cable with no explosion protection |
|
6 |
With signal cable interface adapter and no explosion protection (*2) |
|
E |
For pressure clamp terminal block or MIL cable with explosion protection |
|
F |
With signal cable interface adapter and explosion protection (*2) |
|
3 |
With ISA Standard G3 and temperature (-20 to 70 ºC) |
|
C |
With ISA Standard G3 and high-density installation (-20 to 70 ºC) (*5) |
|
Option Codes |
/A4S00 |
With pressure clamp terminal block for analog [Model: STA4S-00] |
/A4S10 |
With pressure clamp terminal block for analog (with surge absorber) [Model: STA4S-10] |
|
/A4D00 |
With dual-redundant pressure clamp terminal block for analog (*3) [Model: STA4D-00] |
|
/A4D10 |
With dual-redundant pressure clamp terminal block for analog (with surge absorber) (*3) [Part name: STA4D-10] |
|
/PRP |
With prevention pin of false insertion (*4) |
|
/CCC01 |
With connector cover for MIL cable (for flat ribbon cable) [Model: SCCC01] |
n ORDERING INFORMATION
Specify the model and suffix codes.
For selecting the right products for explosion protection, please refer to TI 32S01J30-01E without fail.
SAI143 Analog Input Module (4 to 20 mA, 16-channel, module isolation)
SAI143-S53/A4S00 , SAI143-S53/A4S10 , SAI143-S53/A4D00 , SAI143-S53/A4D10 ,SAI143-S53/PRP, SAI143-S53/CCC01
SAI143-S63/A4S00 , SAI143-S63/A4S10 , SAI143-S63/A4D00 , SAI143-S63/A4D10 ,SAI143-S63/PRP, SAI143-S63/CCC01
SAI143-SE3/A4S00 , SAI143-SE3/A4S10 , SAI143-SE3/A4D00 , SAI143-SE3/A4D10 ,SAI143-SE3/PRP, SAI143-SE3/CCC01
SAI143-SF3/A4S00 , SAI143-SF3/A4S10 , SAI143-SF3/A4D00 , SAI143-SF3/A4D10 ,SAI143-SF3/PRP, SAI143-SF3/CCC01
SAI143-S5C/A4S00 , SAI143-S5C/A4S10 , SAI143-S5C/A4D00 , SAI143-S5C/A4D10 ,SAI143-S5C/PRP, SAI143-S5C/CCC01
SAI143-S6C/A4S00 , SAI143-S6C/A4S10 , SAI143-S6C/A4D00 , SAI143-S6C/A4D10 ,SAI143-S6C/PRP, SAI143-S6C/CCC01
SAI143-SEC/A4S00 , SAI143-SEC/A4S10 , SAI143-SEC/A4D00 , SAI143-SEC/A4D10 ,SAI143-SEC/PRP, SAI143-SEC/CCC01
SAI143-SFC/A4S00 , SAI143-SFC/A4S10 , SAI143-SFC/A4D00 , SAI143-SFC/A4D10 ,SAI143-SFC/PRP, SAI143-SFC/CCC01