MTL5051 Serial Data Communications Isolator IN STOCK
The MTL5051 provides bi-directional serial data communication from
a computer system in safe area to instrumentation in a hazardous
area. It is used to provide a fully floating dc supply for, and serial
data communications to: MTL643, MTL644, MTL646 and MTL647 IS
text displays, other IS instrumentation, keyboards or a mouse. It can
also be used for data communications across a hazardous area.
SPECIFICATION
See also common specification
Location of field equipment
Zone 0, IIC, T4-6 hazardous area
Div 1, Group A hazardous location
Safe-area signal
RS232 or RS422
Hazardous-area signal
MTL640 Series mode:
To hazardous area: 3V signal superimposed on 12V
(nominal) supply
From hazardous area: 5mA signal superimposed on
quiescent current
Across hazardous area communications mode:
To hazardous area: 10mA current source
From hazardous area: 10mA current source
IS RS232/TTL devices mode:
To hazardous area: RS232-compatible signal levels
From hazardous area: TTL/RS232 signals
LED Indicators
Green: power indication
Max. power dissipation within unit
1.7W at 24V, 25mA load
Maximum power consumption (25mA load)
At Vs=20V, 105mA
At Vs=24V, 90mA
At Vs=35V, 70mA
Comms bandwidth
643/4 mode 1200 to 9600 baud
Other modes up to 19.2 kbaud
Safety description
Terminals 1,2,3,4 only 14V, 800mW, 192mA
Terminals 1,3,4 only 14V, 350mW, 88mA
Terminals 1,2,3 only 14V, 450mW, 108mA
Terminals 1,5,6 only 15V, 70mW, 35mA
Terminals 1,2,5,6 only 20V, 460mW, 139mA
Terminals 1,2,3,4,5,6 only 20V, 810mW, 227mA
Hazardous area supply terminal 2
+12V mode 12.0V ± 5% (load <23mA)
+12V mode 8.0V min (load >23 to <50mA)
+5V 5.6V ± 5% (load >23 to <50mA)
Hazardous Interfacing
See MTL640 Series for details of interfacing with MTL643,
MTL644, MTL646 and MTL647 IS text displays.
Across hazardous areas communications mode
The MTL5051 is used in pairs to transfer bi-directional fullduplex
data across hazardous areas, as shown above. Current
switching is used to minimise the bandwidth-limiting effects of
long cables.
Interfacing to an IS keyboard, mouse or other device
Communicating with RS232-level interfaces, such as an IS
keyboard, mouse, etc. is achieved by using one or more
MTL5051 units as required by the device. (TTL level interfaces are
also accommodated by the TTL-compatibility feature of RS232
receivers.) The supply to the IS equipment may be selected to be
either 5V or 12V by switch on top of unit.
Model Number:
Model Number:
MTL5018AC
MTL5501-SR
MTL5510
MTL5510B
MTL5511
MTL5513
MTL5514
MTL5514D
MTL5516C
MTL5517
MTL5521
MTL5522
MTL5523
MTL5523V
MTL5524
MTL5525
MTL5526
MTL5541
MTL5541A
MTL5541AS
MTL5541S
MTL5544
MTL5544A
MTL5544AS
MTL5544D
MTL5544S
MTL5546
MTL5546Y
MTL5549
MTL5549Y
MTL5573
MTL5575
MTL5576-RTD
MTL5576-THC
MTL5581
MTL5582
MTL5582B
MTL5531
MTL5532
MTL5561
MPA5500
MTL5051
MTL5053
MTL5314
MTL5599
SD07
SD16
SD32
SD55
SD07R
SD16R
SD32R
SD55R
SD07X
SD16X
SD32X
SD55X
SD32T3
SD07R3
SD16R3
SD32R3
SD55R3
SDRTD
SDPSTN
SD150X
SD275X
MTL5575
MTL5544D
MTL5546Y
MTL4541
MTL4546Y
MTL5573
MTL5541A
MTL4524
MTL5576-RTD
MTL5051
IOP32
IOP32D
TP48-N-NDI
KFD2-SR2-EX2.W
Any inquires, please feel free to contact us via E-mail, thanks!
-----------------------------------
Lily
HONGKONG XIEYUAN TECH CO., LIMITED
T: 86-027-85568699 F: 86-027-85309780
E-mail: lily@hkxytech.com
Add: 7-A16,Caishen Commercial Plaza,Hankou Railway Station,Wuhan, Hubei, China
Web: www.hkxytech.com